EIT RawMaterials logo

MP-ICDP (Logging tool)


Model id: Mud Parameter, Antares, SN: 1625008

Measurements:

  • pressure
  • electric mud resistivity or mud conductivity
  • temperature
  • total natural gamma

Purpose: mud properties: temperature, pressure, resistivity

Characteristics: Quartzdyne QL20K hi-resolution pressure sensor, PT-1000 temperature sensor (inside housing), flushed electrode array for resistivity; Pressure [MPa], MudRES [Ohmm], MP-TEMP [°C], GR [gAPI]

Specifications:

Vertical resolution:0.100 m
Typical logging speed:8.00 m/min
Maximum pressure:80.0 MPa
Maximum temperature:150℃
Maximum boreholedeviation:50°
Required boreholefluid:
water based mud, low solidsThe borehole has to be filled with a water based mud that has as little solid content as possible.
Minimum borehole diameter:0.075 m
Maximum borehole diameter:0.250 m
----------
Type of datatransfer:
cableData are transferred in real time via a cable.
Required type of logging cable:
4/7 conductor4 & 7 conductor cable types are possible.
Required cablehead:
GO7Connector according to GO 7 standard (7 conductors).
Implement search on winches with this cable head.
Type of signal:
digitalDigital signal transmission.
Maximum cable length:7000 m
Acquisitionsystem (recommended):Antares-ICDP
----------
Length:3 m
Maximum diameter:0.043 m
Weight:70 kg
Belongs to toolstring:
Antares telemetryAlways in combination with and only with the Antares Telemetry Sub TS.
----------
Usage conditons:Only non-commercial research is allowed/welcome.
Additional usage conditions:Logging as service by ICDP OSGLogging as service by ICDP OSG
Additional information available at:https://www.icdp-online.org/fileadmin/icdp/services/img/Logging/OSG_Slimhole_Sondes_Specs_pics_01.pdf

Operator and contact:

Operator:GFZ German Research Centre for Geosciences, Centre for Scientific Drilling
Contact person:Jochem Kück
Email:jochem.kueck@gfz-potsdam.de
Telephone:+49 3312881087
Address: Telegrafenberg
Building A69
14473 Potsdam, Germany


End of I-EDDA database record