EIT RawMaterials logo

DIP-ICDP (Logging tool)


Model id: Dipmeter, Antares, SN: 1204001

Measurements:

  • probe orientation derived from magnetometer and accelerometer/gravimeter data
  • borehole diameter, meassured with four sensors/arms
  • image of the borehole wall's electric resistivity as recorded by four sensor pads, i.e. four (oriented) traces with "white space" in-between (area not covered by pads) that increases with borehole diameter
  • total natural gamma
  • magnetic field amplitude

Purpose: borehole geometry & calliper; dip & dip direction of foliation, layering, fractures; magnetic field amplitude

Characteristics: spacial orientation: 3-axis fluxgate magnetometers, 3-axis accelerometers, four powered caliper arms with electrode pads; resistivity contrast: focused micro currents are induced into the borehole wall from one electrode per pad on each caliper arm and voltage and current are measured with respect to a reference electrode near the tool head; borehole deviation & azimuth, arm-1 azimuth, relative bearing: DEVI, HAZI, P1AZI, RB [deg], borehole caliper: C1 & C2 [mm], magnetic field amplitude: Mx,y,z [nT], 4 oriented traces of electric micro resistivity: Res1,2,3,4 [none], GR [gAPI]; Vertical resolution: micro res: 0.005, orientation: 4, mag field: 0.1; Depth of penetration: micro res: 0.02, orientation: none, mag field: 0.2

Specifications:

Vertical resolution:0.005 m
Penetration depth:0.020 m
Typical logging speed:5.00 m/min
Maximum pressure:80.0 MPa
Maximum temperature:150℃
Maximum boreholedeviation:50°
Required boreholefluid:
conductive liquidThe borehole has to be filled with a conductive liquid.
Minimum borehole diameter:0.075 m
Maximum borehole diameter:0.250 m
----------
Type of datatransfer:
cableData are transferred in real time via a cable.
Required type of logging cable:
4/7 conductor4 & 7 conductor cable types are possible.
Required cablehead:
GO7Connector according to GO 7 standard (7 conductors).
Implement search on winches with this cable head.
Type of signal:
digitalDigital signal transmission.
Maximum cable length:7000 m
Acquisitionsystem (recommended):Antares-ICDP
----------
Length:4 m
Maximum diameter:0.052 m
Weight:20 kg
Belongs to toolstring:
Antares telemetryAlways in combination with and only with the Antares Telemetry Sub TS.
----------
Usage conditons:Only non-commercial research is allowed/welcome.
Additional usage conditions:Logging as service by ICDP OSG
Additional information available at:https://www.icdp-online.org/fileadmin/icdp/services/img/Logging/OSG_Slimhole_Sondes_Specs_pics_01.pdf

Operator and contact:

Operator:GFZ German Research Centre for Geosciences, Centre for Scientific Drilling
Contact person:Jochem Kück
Email:jochem.kueck@gfz-potsdam.de
Telephone:+49 3312881087
Address: Telegrafenberg
Building A69
14473 Potsdam, Germany